E140 SERIES PRESSURE REGULATORS
Short Description:
BALANCED VALVE FULL SEAL AT ZERO FLOW OPTIONAL MAXIMUM AND/OR MINIMUM PRESSURE SLAM-SHUT VALVE WIDE OUTLET-PRESSURE REGULATION RANGE ACCURATE PRESSURE REGULATION E140 serials regulator is a diaphragm and spring controlled direct acting regulator.Widely used in medium-sized commercial facilities and regional.Built-in with relief valve and ultra low-pressure safety devices.The regulator has characteristics of simple structure,convenient operation,easy maintenance online,etc. TECHNICAL ...
BALANCED VALVE
FULL SEAL AT ZERO FLOW
OPTIONAL MAXIMUM AND/OR MINIMUM PRESSURE SLAM-SHUT VALVE
WIDE OUTLET-PRESSURE REGULATION RANGE
ACCURATE PRESSURE REGULATION
E140 serials regulator is a diaphragm and spring controlled direct acting regulator.Widely used in medium-sized commercial facilities and regional.Built-in with relief valve and ultra low-pressure safety devices.The regulator has characteristics of simple structure,convenient operation,easy maintenance online,etc.
TECHNICAL DATA
Inlet pressure | Pemax.≤6 bar | |
Shut-off when over-pressure | Who:22.5-450 mbar | |
Inlet pressure range | Bpe: 0.5-5 bar | |
Shut-off when low-pressure | Whu:12.8-250 mbar | |
Outlet pressure set range | standard | Wh: 15-70 mbar |
HP | Wh:70-300 mbar | |
Shut-off accuracy | AG: ≤5% | |
Accuracy class | AC: ±5% | |
Response time | Ta: ≤1 sec | |
Shut-off pressure class | SG: +10% | |
Flow rate (natural gas) | Qmax. ≤900Nm³/h | |
Operating temprature | -20℃-60℃ | |
Connection size | DN50 PN16 | |
Ambient temperature | -30℃-60℃ | |
Weight | Low pressure type:19kgHigh pressure type:21kg |
CAPACITY CHART
Outletpressure
(mbar) |
Inlet pressure (bar) | ||||||||||||||
0.05 | 0.07 | 0.1 | 0.15 | 0.2 | 0.3 | 0.4 | 0.5 | 0.75 | 1 | 1.5 | 2 | 3 | 4 | ||
STANDARD | 15 | 80 | 100 | 120 | 150 | 170 | 220 | 250 | 280 | 340 | 400 | 500 | 600 | 650 | 750 |
20 | 75 | 100 | 120 | 150 | 170 | 220 | 250 | 280 | 340 | 400 | 500 | 600 | 650 | 750 | |
30 | 60 | 90 | 110 | 150 | 170 | 220 | 250 | 280 | 340 | 400 | 500 | 600 | 650 | 750 | |
40 | - | 80 | 100 | 140 | 170 | 210 | 250 | 280 | 340 | 400 | 500 | 600 | 650 | 750 | |
50 | - | 70 | 90 | 140 | 160 | 210 | 240 | 270 | 340 | 400 | 500 | 600 | 650 | 750 | |
75 | - | - | 70 | 90 | 150 | 200 | 240 | 270 | 340 | 400 | 500 | 600 | 650 | 750 | |
AP |
100 | - | - | - | - | 140 | 190 | 230 | 250 | 340 | 400 | 500 | 600 | 650 | 750 |
150 | - | - | - | - | 100 | 170 | 220 | 250 | 330 | 390 | 500 | 600 | 650 | 750 | |
200 | - | - | - | - | - | 140 | 200 | 240 | 310 | 380 | 500 | 600 | 650 | 750 | |
300 | - | - | - | - | - | - | 150 | 210 | 310 | 380 | 500 | 600 | 650 | 750 |